Fire Protection Technology assignment

Fire Protection Technology

Refer to the Points to Ponder Scenario in the Unit II Lesson to respond to this discussion board. Do you think the byproducts of combustion would reach the warehouse’s fire protection, detection, or suppression system to alarm or suppress the fire? Why, or why not?

Please include the name of the person or question to which you are replying in the subject line. For example, “Tom’s response to Susan’s comment.”
ALSO PLEASE RESPOND TO ANOTHER STUDENTS COMMENT BELOW

Don't use plagiarized sources. Get Your Custom Essay on
Fire Protection Technology assignment
Just from $9/Page
Order Essay

Frank:

Looking at the scenario,there are numerous items that stand out as “red flags”to me. First was the fact that the system was not rated for the combustible storage. That means that the system would not put out enough GPM to suppress or control the fire. There would also be a good chance that the system would be overrun by the amount of fire and heat produced and would have no effect at all but maybe slowing the fire for a few minutes before it overran the system. Secondly, The report states that the systemwas barely operational. It didn’t say why. I know during unit 1 there were issues with the availiable water coming into the building was inadequate due to the old pipes in the area. It could be a housekeeping issue or something was broken and was in the process of being fixed. Any way, there should have been a fire watch and getting this system operational should have been a top priority. Third, the power was out and there was no back up power to the building due to flooding. All of the fire suppression and alarm systems should have their own emergency backup in case of power failure. Fourth, the detectors were only in the ceiling. That is not good for any fire that starts on the ground level or in those stacks. With that much space between the detectors and combustibles, by the time the heat reached the detectors to alarm it, the fire would be extremely large and would most likely overrun the suppression system possibly before it even activates. SInce“unchecked fire” doubles in size every 2 minutes, without a lower temp detector closer to the ground, the system would not even have a chance to get this fire under control, even if it activated. In closing, I do not think that the system would have had enough time to respond or activate in this scenario. The entire system was designed incorrectly for this building. The fire would have had way too much time to build before the system would even activate.

Place your order
(550 words)

Approximate price: $22

Calculate the price of your order

550 words
We'll send you the first draft for approval by September 11, 2018 at 10:52 AM
Total price:
$26
The price is based on these factors:
Academic level
Number of pages
Urgency
Basic features
  • Free title page and bibliography
  • Unlimited revisions
  • Plagiarism-free guarantee
  • Money-back guarantee
  • 24/7 support
On-demand options
  • Writer’s samples
  • Part-by-part delivery
  • Overnight delivery
  • Copies of used sources
  • Expert Proofreading
Paper format
  • 275 words per page
  • 12 pt Arial/Times New Roman
  • Double line spacing
  • Any citation style (APA, MLA, Chicago/Turabian, Harvard)

Our guarantees

Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.

Money-back guarantee

You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.

Read more

Zero-plagiarism guarantee

Each paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.

Read more

Free-revision policy

Thanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.

Read more

Privacy policy

Your email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.

Read more

Fair-cooperation guarantee

By sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.

Read more
error: Content is protected !!
Open chat
1
Need assignment help? You can contact our live agent via WhatsApp using +1 718 717 2861

Feel free to ask questions, clarifications, or discounts available when placing an order.
 + 1 (718) 717-2861           + 44 161 818 7126           [email protected]
  (718) 717-2861         [email protected]